SCR 3-1152

SCR 3-1152: Change STANDARD_VALUE_TYPE and MAXIMUM_LENGTH for SPACECRAFT_POINTING_MODE to SUGGESTED and 25 respectively

Priority: medium


Problem Summary

SPACECRAFT_POINTING_MODE has a standard value type (STANDARD_VALUE_TYPE) of DYNAMIC which requires PDS approval for adding new standard values. Values are limited to twelve (12) characters. The Odyssey THEMIS team would like to use this keyword with several new values including some that will be devised in the future and aren’t currently known. An example of a new value is “HGA_MITIGATION_R-10”. There would appear to be little merit in requiring formal approval for of values of this type. The currently proposed addition, HGA_MITITGATION_R_10 at 19 characters exceeds the allowed length of twelve (12) characters.


Working Group

P. Garcia (lead) B. Sword

Originator: B. Sword


Standards Change Request

VersionDateAuthor(s)FormatNote
12009-06-22B. Sword and P. GarciaDOC
PDF

Discussion


Supplementary Material


Status


Votes

The Tech Group votes at the 07/29/09 Standards Telecon to reject the SCR by a vote of 7-0-2 (reject-don’t reject-absent)

NodeRepresentativeVersion 1
ATMabsent
ENE. Ryereject
GEOS. Slavneyreject
IMGP. Garciareject
NAIFB. Semenovreject
PPIT. Kingreject
RINGSabsent
RSD. Simpsonreject
SBNA. Raughreject